Chloride® FP40R DC UPS
Designed to provide a simple, fast and cost effective solution for DC power requirements.
TypeDC UPS /
Natural cooling
Ratings24...220 Vdc |
25...400 A
TechnologySCR
Chloride® FP40R DC UPS
Designed to provide a simple, fast and cost effective solution for DC power requirements.
TypeDC UPS /
Natural cooling
Ratings24...220 Vdc |
25...400 A
TechnologySCR
Market & Industry Type
Power transmission and distribution
Continuous process industries
Petrochemical and chemical industries
Water and wastewater industries
Downloads
Features & Benefits
Read lessKey Advantages
Improved reliability
Provided by a fully controlled SCR bridge and a reduced quantity of components.
Adaptability
Thanks to a selection of industrialized options and an easy parameter settings for quick onsite adjustments.
Simplicity
Of the product design to improve MTBF and to reduce MTTR.
Low Voltage Ripple
To optimize battery life.
Low inrush current
< 8In not to oversize mains power supply (3-phase).
Compact design
With the capability to integrate the battery in the charger cabinet.
Human-Machine Interface (HMI)
To deliver appropriate information level to the user.
Ingress protection
TexUp to IP55 for harsh environmental conditions.
Compatibility
With nickel-cadmium and lead-acid batteries, vented or gas-recombination types.
Galvanic isolation
Between input and output.
Digital control
Digital control and monitoring.
Wide choice
Wide choice of configurations and options.
Technical Specification
Read lessInput
Model
1-Ph: FP40R10
3-Ph: FP40R30
Input voltage (other voltage on request)
1-Ph: 230 VAC ± 10%
3-Ph: 400 VAC ± 10%
Inrush current
1-Ph: < 15 ln
3-Ph: < 8 ln
Frequency range
From 47 to 63 Hz
Output
Available rating
See ratings table
Nominal DC voltage
24/48/110/220V
Static regulation
1 %
Voltage ripple 1-ph
Disconnected battery (< 2.5 %)
Voltage ripple 3-ph
Disconnected battery (< 0.7 %)
Supervision
Charger status
Charger status and alarms on displaying Unit
Displayed values
Output voltage, output current, battery Current
Remote signaling
With 4 dry contacts
Event log
Up to 100 events
Battery
Type
Lead acid or nickel cadmium, vented or recombination
Autonomy
From few minutes to several hours, as required
General Data
Rectifier efficiency
From 83 % to 94 % (according to model)
Operating temperature
From 0 to 40 °C (without system derating)
Storage temperature
From -20 °C to +70 °C (battery excluded)
Relative humidity
< 95 % non condensing at 20 °C
Operating altitude
1000 m (without system derating)
Cooling
Natural or fan-assisted (according to rating)
External ingress protection
IP20
Internal protection
Internal protection
Noise (at 1m in front of the unit)
≤ 60 dB
Isolation
Input - Output 2500 VAC / 1 minute
Frame colour
RAL 7035 or RAL 7032
Dimensions
Varying according to ratings and options (consult us)
Output current (A) vs Output voltage (Vdc)
Ratings with 1-phase input
24 Vdc: 100A
48 Vdc: 40/60/100A
110-125 Vdc : 25/40/60/100A
220 Vdc: 25A
Ratings with 3-phase input
24 Vdc: 35/65/100/160/220/300/400A
48 Vdc: 35/65/100/160/220/220/300/400A
110-125 Vdc: 35/65/100/160/220/300/400A
220 Vdc: 35/65/100/160/220/300A
Options
Charger
Input circuit breaker or molded case circuit breaker (16 kA or 36 kA)
Position contact on AC input circuit breaker
Paralleling diode
Dropping diode
DC earth fault monitor
Customer connection on terminal blocks
Ultra low voltage ripple < 0.1 % (48 V)
Measurements of AC input voltage, current and frequency
Battery
Battery protection (fuses or circuit breaker with contact)
Protection against battery reversed polarity
Battery Low Voltage Disconnection (LVD)
Battery Low Voltage Disconnection (LVD) Temperature sensor for battery charge compensation
Test battery presence or test battery capacity
Mechanical
Operating temperature up to 55 °C (with system derating)
External ingress protection IP21, 23, 40, 41, 43, 55
Space heater with hygrostat and/or thermostat
Internal lighting
100 mm or 200 mm base frame
Lifting eyes
DC Load
DC output protection (fuses or circuit breaker with contact)
Distribution board (circuit breaker with or without contact)
Communication
Modbus RS485
Remote alarm up to 8 additional relays
Special Request
Configuration
Single rectifier with no battery
Dual charger in single cabinet
Dual charger with shared battery
Battery
Batteries in charger cabinet (on shelves or drawers)
Mechanical
Other RAL painting colour
European Directives
Low voltage directive
2006/95/EC (before April 2016)
2014/35/EU (after April 2016)
EMC directive
2004/108/EC (before April 2016)
2014/30/EU (after April 2016)
Compliances
IEC/NF EN 60146-1-1: 2009
Semiconductor converters - Part 1-1: Specification of basic requirements
IEC/NF EN 61000-6-2: 2006
Electromagnetic compatibility (EMC) - Part 6-2: Generic standards - Immunity for industrial environments
IEC/NF EN 61000-6-4: 2007 AMD1: 2011
Electromagnetic compatibility (EMC) - Part 6-4: Generic standards - Emission standards for industrial environments
IEC/NF EN 61439-1: 2012
Low voltage switchgear and controlgear assemblies - Part1: General rules
IEC/NF EN 60950-1: 2013 AMD2: 2014
Information technology equipment - Safety - Part 1: General requirements
NF C58-311: 1990
Procedure for type tests for rectifier-battery charger and batteries