Chloride® CP70Z AC UPS

CP as Customized Product. The most advanced product in terms of possibilities.

Enquire

UPS TypeAC IEC/UL

Ratings5 to 500+ kVA

TechnologySCR/IGBT

Chloride® CP70Z AC UPS

CP as Customized Product. The most advanced product in terms of possibilities.

Enquire

UPS TypeAC IEC/UL

Ratings5 to 500+ kVA

TechnologySCR/IGBT

Market & Industry Type

  • Oil & Gas industries, offshore and onshore

  • Refining and petrochemical plants

  • Power generation plants

  • Rail transport

  • Process industries

Availability

Maintainability

The easiest on the market with total components front access.

Reliability

Innovative internal temperature reduction, through dual redundant cooling channels.

Multiplied redundancy with Chloride® Patented Smart Parallel Switching function that dynamically controls paralleled systems.

Key advantages

User friendly

Large color touch screen with 2000-event exportable log.

One of the best on the Industrial UPS Market.

USB access

Export of all the recorded events using USB flash drive.

Memorization of complete electronic settings for future maintenance needs.

Batteries compatibility

Innovative full integration with SMC/Salt Batteries (Sodium Metal Chloride Batteries).

Full compatibility with Lead-acid, nickel-cadmium batteries, sealed or vented and Lithium-Ion.

Low THDi

6 - or 12-pulse thyristor rectifier.

Down to 5% THDI in 12-pulse SCR system with harmonic filters.

Life time

Designed for 20+ years of continuous operation with appropriate maintenance plan.

Input

AC Voltage

3 X 400 V (380, 415) (other available on request)

 

Voltage Tolerance

+/- 10%

Frequency

50 Hz (60 Hz)

Frequency Tolerance

+/- 5%

Inrush current

≤ 10 x ln (other available on request)

Output

AC Voltage Single phase

1 x 230 V (220, 240) ; 1 x 110 V (115, 120) (other available on request)

AC Voltage Three phase

3 x 400 V (380, 415) ; 3 x 220 V (200, 208, 230) (other available on request)

Frequency

50 Hz (60 Hz)

Frequency stability with internal oscillator

+/- 0.05%

Frequency stability with reserve synchronism

+/- 3 % (from 1 to 5% adjustable)

Voltage stability (for 0 to 100 % load variation): Static

Voltage stability (for 0 to 100 % load variation) : Static

Voltage stability (for 0 to 100 % load variation): Dynamic

VFI SS 111 as per IEC/EN 62040-3, class 1

Inverter overload capability: 1 minute

150 % of nominal power

Inverter overload capability: 10 minutes

125 % of nominal power

Short circuit clearance (in % of nominal current): 1-ph output

250 % / 100 ms - 175 % / 5s

Short circuit clearance (in % of nominal current): 3-ph output Ph-N

315 % / 100 ms - 220 % / 5s

Short circuit clearance (in % of nominal current): 3-ph output Ph-Ph

190 % / 100 ms - 135 % / 5s

Harmonic voltage distortion: With 100% linear load

< 3%

Harmonic voltage distortion: With 100% non-linear load

SS as per IEC/EN 62040-3

Allowable power factor

0.5 lagging to 0.5 leading

Battery

Battery

Salt Metal Chloride, Lead acid or nickel cadmium, vented or recombination

Autonomy

From few minutes to several hours, on request

Battery current limitation (typical, float, & boost modes)

0.1 C (lead-acid battery) / 0.2 C (nickel-cadmium battery)

General Data

Operating temperature

0 to 40 °C (-20°...55°C on request)

Storage temperature

-20 to +70°C

Relative humidity

< 95% non condensing

Operating altitude

1000m max without derating (other available on request)

Cooling

Forced ventilation

Efficiency

Up to 90% according to rating

External protection

IP 20 according to IEC 60529 (other available on request)

Internal protection

Protection against unintentional direct contact, as per IEC 60590-1/62477-1

Cabinet colour

Grey RAL 7032 (other available on request)

Dimensions

Varying according to ratings and options

Ratings

110-120 Vdc

5 / 10 / 20 / 30 / 40 / 50 / 60 kVA

220-240 Vdc

10 / 20 / 30 / 40 / 50 / 60 / 80 / 100 / 120 / 160 / 200 / 250 / 320 / 400 / 500 kVA

400 Vdc

40 / 50 / 60 / 80 / 100 / 120 / 160 / 200 / 250 / 320 / 400 / 500 kVA

Standards

IEC62040-1:2017

Uninterruptible power systems (ups) - Part 1: Safety requirements

IEC62040-2:2016

Uninterruptible power systems (UPS) -Part 2: Electromagnetic compatibility (EMC) requirements

IEC62040-3:2011

Uninterruptible power systems (UPS) - Part 3: Method of specifying the performance and test requirements

IEC61439-1:2011

Low voltage switchgear and controlgear assemblies - Part 1: General rules

IEC60529:1989+AMD1:1999

Degrees of protection provided by enclosures (IP Code)

IEC60076-11:2004

Power transformers - Part11: Dry type transformers

Conformity

Low voltage directive

2006/95/EC and 2014/35EU

EMC directive

2004/108/EC and 2014/30/EU

CE Mark

Yes

Options

Wide range of options

Refer to datasheet in download section