Chloride® FP60Z AC UPS

Industrial UPS system offering a full-IGBT innovative design. A wide range of possible options.

Enquire

UPS TypeAC IEC

Ratings5 to 250 kVA

TechnologyFull IGBT

Chloride® FP60Z AC UPS

Industrial UPS system offering a full-IGBT innovative design. A wide range of possible options.

Enquire

UPS TypeAC IEC

Ratings5 to 250 kVA

TechnologyFull IGBT

Market & Industry Type

  • Petrochemical and Chemical

  • Minings/Metals

  • Power generation plants

  • Oil & Gas

  • Water and Wastewater

  • Transportation (rail, metro, tramway)

  • Continuous manufacturing processes

Key advantages

Safety

Bidirectional rectifier to perform battery deep discharging.

Smart access to UPS data

Large color LCD touch-pad for user interface.

USB access

Export of all the recorded events using USB flash drive.

Best-in-class performance to optimize expenses

Reduced CAPEX - Upstream transformer, switchgear and cables are downsized thanks to high input power factor, low THDi rejection and low inrush current.

Proven digital Vector Control technology to control the output waveform, even on non linear loads.

Controlled OPEX

Lower power consumption thanks to high efficiency.

Industrial-grade maintainability

Innovative design allowing an easy front access to all components.

Removable ID Cards which safeguard the UPS parameters and facilitate control board replacement.

Configurable active mimic diagram.

Industrial flexibility

Fit-for-purpose battery selection.

Galvanic isolation: either output and/or input transformers.

Wide range of electrical and mechanical options.

Input

AC Voltage

3 X 400 V (380, 415) (other available on request)

 

Voltage Tolerance

+/- 10%

Frequency

50 Hz (60 Hz)

Frequency Tolerance

+/- 5%

Inrush current

≤ 10 x ln (other available on request)

Output

AC Voltage Single phase

1 x 230 V (220, 240) ; 1 x 110 V (115, 120) (other available on request)

AC Voltage Three phase

3 x 400 V (380, 415) ; 3 x 220 V (200, 208, 230) (other available on request)

Frequency

50 Hz (60 Hz)

Frequency stability with internal oscillator

+/- 0.05%

Frequency stability with reserve synchronism

+/- 3 % (from 1 to 5% adjustable)

Voltage stability (for 0 to 100 % load variation): Static

Voltage stability (for 0 to 100 % load variation) : Static

Voltage stability (for 0 to 100 % load variation): Dynamic

VFI SS 111 as per IEC/EN 62040-3, class 1

Inverter overload capability: 1 minute

150 % of nominal power

Inverter overload capability: 10 minutes

125 % of nominal power

Short circuit clearance (in % of nominal current): 1-ph output

250 % / 100 ms - 175 % / 5s

Short circuit clearance (in % of nominal current): 3-ph output Ph-N

315 % / 100 ms - 220 % / 5s

Short circuit clearance (in % of nominal current): 3-ph output Ph-Ph

190 % / 100 ms - 135 % / 5s

Harmonic voltage distortion: With 100% linear load

< 3%

Harmonic voltage distortion: With 100% non-linear load

SS as per IEC/EN 62040-3

Allowable power factor

0.5 lagging to 0.5 leading

Battery

Battery

Salt Metal Chloride, Lead acid or nickel cadmium, vented or recombination

Autonomy

From few minutes to several hours, on request

Battery current limitation (typical, float, & boost modes)

0.1 C (lead-acid battery) / 0.2 C (nickel-cadmium battery)

General Data

Operating temperature

0 to 40 °C (-20°...55°C on request)

Storage temperature

-20 to +70°C

Relative humidity

< 95% non condensing

Operating altitude

1000m max without derating (other available on request)

Cooling

Forced ventilation

Efficiency

Up to 90% according to rating

External protection

IP 20 according to IEC 60529 (other available on request)

Internal protection

Protection against unintentional direct contact, as per IEC 60590-1/62477-1

Cabinet colour

Grey RAL 7032 (other available on request)

Dimensions

Varying according to ratings and options

Ratings

110-120 Vdc

5 / 10 / 20 / 30 / 40 / 50 / 60 kVA

220-240 Vdc

10 / 20 / 30 / 40 / 50 / 60 / 80 / 100 / 120 / 160 / 200 / 250 / 320 / 400 / 500 kVA

400 Vdc

40 / 50 / 60 / 80 / 100 / 120 / 160 / 200 / 250 / 320 / 400 / 500 kVA

Standards

IEC62040-1:2017

Uninterruptible power systems (ups) - Part 1: Safety requirements

IEC62040-2:2016

Uninterruptible power systems (UPS) -Part 2: Electromagnetic compatibility (EMC) requirements

IEC62040-3:2011

Uninterruptible power systems (UPS) - Part 3: Method of specifying the performance and test requirements

IEC61439-1:2011

Low voltage switchgear and controlgear assemblies - Part 1: General rules

IEC60529:1989+AMD1:1999

Degrees of protection provided by enclosures (IP Code)

IEC60076-11:2004

Power transformers - Part11: Dry type transformers

Conformity

Low voltage directive

2006/95/EC and 2014/35EU

EMC directive

2004/108/EC and 2014/30/EU

CE Mark

Yes

Options

Wide range of options

Refer to datasheet in download section