Chloride® CP70RC DC UPS

CP as Customized Product. The most advanced product in terms of possibilities. A force cooled product.

Enquire

UPS TypeDC UPS /
Forced cooling

Ratings24...220 Vdc |
200...1300A

TechnologySCR

Chloride® CP70RC DC UPS

CP as Customized Product. The most advanced product in terms of possibilities. A force cooled product.

Enquire

UPS TypeDC UPS /
Forced cooling

Ratings24...220 Vdc |
200...1300A

TechnologySCR

Market & Industry Type

  • Oil and Gas industries, offshore and onshore

  • Refining and petrochemical plants

  • Power generation plants

  • Rail transport

  • Process industries

Availability

Maintainability

The easiest on the market with total components front access.

Reliability

Innovative internal temperature reduction, through dual redundant cooling channels.

Multiplied redundancy with Chloride® Patented Smart Parallel Switching function that dynamically controls paralleled systems.

Key advantages

User friendly

Large color touch screen with 2000-event exportable log.

One of the best on the Industrial UPS Market.

USB access

Export of all the recorded events using USB flash drive.

Memorization of complete electronic settings for future maintenance needs.

Batteries compatibility

Innovative full integration with SMC/Salt Batteries (Sodium Metal Chloride Batteries).

Full compatibility with Lead-acid, nickel-cadmium batteries, sealed or vented and Lithium-Ion.

Life time

Designed for 20+ years of continuous operation with appropriate maintenance plan.

Inrush current

Reduced ≤ 10xIn to avoid oversizing upstream protection and 2-step strat-up.

Cooling

Forced ventilation to reduce the foot print.

Input

AC voltage

3 x 400 V (380, 415)

Voltage tolerance

+/- 10 %

Neutral configuration

Any configuration, with or without neutral

Frequency

50 Hz (60 Hz)

Frequency tolerance

+/- 5 %

Frequency range (temporary)

45 Hz to 65 Hz (with 50 Hz nominal)

Total harmonic current distorsion (THDI)

< 34 % (6-pulse version)< 10 % (12-pulse version)

Inrush current

< 10 x In (for 6-pulse and 12-pulse)< 5 x In (for 12-pulse + harmonic filter option)

Output

Nominal DC voltage

24 V ; 48 V ; 110-127 V ; 220-240 V ; 400 V

Output DC voltage range

17-40 V ; 36-75 V ; 88-160 V ; 176-300 V ; 296-550 V

Voltage stability (in stabilized floating mode, input within tolerance)

Unitary system +/-1 %

Voltage stability (in stabilized floating mode, input within tolerance)

Parallel systems +/-1 % to +/-2 %

Voltage ripple

≤ 1 % RMS, in float mode, battery disconnected

Current limitation

I nominal

Battery

Type

Salt Metal Chloride, Lead acid or nickel cadmium, vented or recombination

Autonomy

From few minutes to several hours, on request

Battery current limitation (typical, float, & boost modes)

0.1 C (lead-acid battery) / 0.2 C (nickel-cadmium battery)

General data

Operating temperature

0 to 40 °C (-20°...55°C on request)

Storage temperature

-20 to +70 °C

Relative humidity

< 95 % non condensing

Operating altitude

1000 m max without derating (other available on request)

Cooling

Forced ventilation

Efficiency

81 % to 97 % according to rating

External protection

IP 20 according to IEC 60529 (other available on request)

Noise (at 1m in front of the unit)

60-72 dB according to rating

Cabinet color

Grey RAL 7032 (other available on request)

Dimensions

Varying according to ratings & options

Ratings

Output voltage 24 Vdc

Output current (A) 200...1200

Output voltage 48 Vdc

Output current (A) 200...1200

Output voltage 110-127 Vdc

Output current (A) 200...1200

Output voltage 220-240 Vdc

Output current (A) 200...1200

Output voltage 400 Vdc

Output current (A) 200...1200