XP90i DC/AC UPS - ATEX IECEx
Chloride® XP DC/AC UPS Inverter systems are tailor-made solutions designed to operate in the hazardous atmosphere.
UPS TypeDC/AC Inverter
IECEx
Rating< 80 kVA
TechnologyIGBT
XP90i DC/AC UPS - ATEX IECEx
Chloride® XP DC/AC UPS Inverter systems are tailor-made solutions designed to operate in the hazardous atmosphere.
UPS TypeDC/AC Inverter
IECEx
Rating< 80 kVA
TechnologyIGBT
Market & Industry Type
Offshore production process in Explosion-risk areas
Wellhead platforms / Unmanned platforms
Pipelines instrumentation
Refineries
Downloads
Features & Benefits
Read lessKey features
Small footprint
To optimize space on offshore platform.
Durability
Optimized thermal management.
Immunity
Strong immunity to perturbations.
Safe control, door closed
Allows the user to operate the switches, circuit breakers, and control buttons door closed.
Smart access to UPS data
Large graphical user interface on the front.
Safe and easy maintenance
Once open, the front door gives direct access to all components.
Alarms
Embedded event logger (up to 2000 events).
Close range Wi-Fi module - To download the event logger without opening the equipment enclosure.
Technical Specification
Read lessOutput
AC Voltage
1 x 230V (220, 240)
1 x 110V (115, 120)
3 x 400 V (380, 415)
Frequency
50 Hz (60 Hz)
Overload inverter: 1 minute
150 % of nominal power
Overload inverter: 10 minutes
125 % of nominal power
Short circuit clearance: 1-ph output (in % of nominal current)
250 %/100 ms - 175 %/5 s
Short circuit clearance: 3-ph output (in % of nominal current)
315 %/100 ms - 220 %/5 s (Ph-N)
Power factor
0.8 lagging
Allowable crest factor
3/1
Battery
Type
Valve Regulated Lead Acid (VRLA) Recombinaison Nickel Cadmium
Autonomy
From few minutes to several hours, as per customer’s requirement
Battery current limitation (typical, float, mode)
0.1 (Lead Acid or Nickel Cadmium battery)
Battery temperature compensation
-3 mV / °C / cell
General Data
Operating temperature
Up to 55°C
Relative humidity
100% condensing
Operating altitude
1000m max without derating
Cooling
Natural
Enclosure
Design
ATEX/IECex certified forZone1, II 2G Ex d IIB+H2 T3 (IEC 60079)
Material
Stainless steel (SS316L),Carbon steel (mild steel) or Aluminum
External ingress protection
IP 66 according to IEC 60529
Dimensions
Varying according to ratings & options
Example of Chloride UPS
The objective of this video is to show a Chloride full solution implemented with explosion proof UPS + battery implemantation + battery monitoring system + software application.