Chloride® FP70ZE AC UPS
Industrial UPS system with innovative full IGBT design. A wide range of benefits such as low THDi, low power factor, high efficiency, small footprint.
UPS TypeAC IEC/UL
Ratings5 to 80 kVA
TechnologyFull IGBT
Chloride® FP70ZE AC UPS
Industrial UPS system with innovative full IGBT design. A wide range of benefits such as low THDi, low power factor, high efficiency, small footprint.
UPS TypeAC IEC/UL
Ratings5 to 80 kVA
TechnologyFull IGBT
Market & Industry Type
Decarbonisation (Solar, CCS, H2, Wind Turbines)
Petrochemical and Chemical
Minings/Metals
Power generation plants
Water and Wastewater
Transportation (rail, metro, tramway)
Continuous manufacturing processes
Features & Benefits
Read lessKey advantages
Fooprint
Compact footprint -20% to -45% vs traditional technologies
CO2 footprint
Reduction up to -25%
Battery innovation
Sodium Metal Chloride (SMC) batteries integration
Safety
Bidirectional rectifier to perform battery deep discharging.
Smart access to UPS data
Large color HMI touch-pad for better user interface.
USB access
Export of all the recorded events using USB flash drive.
Best-in-class performance to optimize expenses
Reduced CAPEX - Upstream transformer, switchgear and cables are downsized thanks to high input power factor, low THDi rejection and low inrush current.
Proven digital Vector Control technology to control the output waveform, even on non linear loads.
Controlled OPEX
Lower power consumption thanks to high efficiency
Industrial-grade maintainability
Innovative design allowing an easy front access to all components.
Industrial flexibility
Fit-for-purpose battery selection.
Galvanic isolation: either output and/or input transformers.
Wide range of electrical and mechanical options.
Technical Specification
Read lessInput
AC Voltage
3-ph+N 208...690 Vac ph-ph ± 10 % (tolerances depend on the voltages)
Inrush current
≤ 1 In (without input transformer)
≤ 8 In (with input transformer)
Power factor
Up to 0.99
Frequency range
50 Hz (60 Hz factory setting) ± 5 %
Embedded input features
AC input isolator switch
Surge protection with MOV lightning arrestors
Max allowed voltage distortion, THDv from mains
8%
Output
AC Voltage
1-ph: 230 Vac (208, 220, 240) ; 110 Vac (115, 120, 127)
3-ph: 400 Vac (380, 415) ; 208 Vac (190, 200, 220)
Frequency stability
With internal oscillator ± 0.1 %
With reserve synchronism ± 1 % (1 to 4 % adjustable)
Voltage stability
(0-100% load variation)
Static ± 1 % Dynamic VFI SS 11 as per IEC62040-3, class 1
Overload inverter
(in % of nominal power)
150 %/1 min - 125 %/10 min at nominal output voltage
Short-circuit clearance
(in % of nominal current)
1-ph and 3-ph: 250 %/100 ms - 150 %/5 s
Voltage distorsion
With 100 % linear load < 2 %
With 100 % non linear load < 5 % as per IEC62040-3
Allowable power factor
0.5 lagging to 0.5 leading
Allowable crest factor
3/1
Embedded output features
Output switch
Output isolation transformer class H
Battery
Battery
SMC (Sodium Metal Chloride) , Lead acid or nickel cadmium, vented or recombination
Recommended number of cells
Lead Acid
110 Vdc (52 to 72)
220 Vdc (104 to 132)
400 Vdc (174 to 220)
Recommended number of cells
Nickel Cadmium
110 Vdc (88 to 94)
220 Vdc (176 to 184)
400 Vdc (296 to 307)
Battery current limitation
0.1 C (Lead Acid) / 0.2 C (Nickel Cadmium)
Embedded battery features
Inbuilt battery circuit breaker with aux. contact
Battery reverse polarity protection and indication
Battery Low Voltage Disconnection (LVD)
Battery test, automatic or manual mode
Battery room temperature sensor for battery charge compensation
General Data
Efficiency
Up to 91 % (according to rating and config.)
Operating temperature
From 0 to 40 °C (without system derating)
T°C operating / Storage
0...40 °C without derating system / -20...70 °C battery excluded
Relative humidity
< 95 % non condensing at 20 °C
Operating altitude
1000 m (without system derating)
Cooling
Fan assisted
Ingress protection
Internal IP20 - external IP42
Noise (at 1m in front of the unit)
62 to 72 dB (according to rating)
Input/output isolation
2500 VAC / 1 minute
Feet
100 mm height with feet cover
Gland plate
Aluminium non-magnetic, 3 mm thickness
Dimensions & colour
From 1 x 800 mm to 2 x 1200 mm width / RAL 7035
Embedded system features
Internal cabinet lighting / Lifting Eyes
Auxiliary power socket
Display languages
English, French, Spanish (factory settings)
Output Power (kVA)
110 Vdc
5 / 10 / 20 kVA
220 Vdc
10 / 20 / 30 / 40 / 50 / 60 kVA
400 Vdc
40 / 50 / 60 / 80 kVA
Standards
IEC62040-1
Semiconductor converters - Part 1-1: Specification of basic requirements
IEC62040-2
Electromagnetic compatibility (EMC) - Part 6-2: Generic standards - Immunity for industry
IEC62040-3
Electromagnetic compatibility (EMC) - Part 6-4: Generic standards - Emission for industry
IEC61439-1
Low voltage switchgear and controlgear assemblies - Part1: General rules
Other
Type tests for rectifier-battery charger and batteries
Conformity
Low voltage directive
2006/95/EC (before April 2016)
2014/35/EU (after April 2016)
EMC directive
2004/108/EC (before April 2016)
2014/30/EU (after April 2016)
CE Mark
Yes
Intermediate DC Circuit
Nominal DC Voltage
110 / 220 / 400 Vdc
Voltage stability in steady state
≤ 1 % in float mode (input within tolerance)
Voltage ripple
≤ 1 % RMS (with and without battery connected)
Current limitation
I nominal
Charging characteristic
IU according to DIN 41773
Options
Rectifier
Input isolation transformer
Special 1-ph or 3-ph input voltage (up to 3 x 690 Vac)
Input voltage tolerance from - 20 % to + 15 %
Input circuit breaker with aux. contact and breaking capacity up to 70 kA
Reverse phase sequence alarm Automatic input phase failure adaptation
Battery
Protection box (circuit breaker), black start, automatic or manual mode ; DC earth fault detection
Output
Circuit breaker with aux. contact
Emergency Power Off
Reserve
Circuit breaker with aux contact
Reserve isolation transformer (H class)
Reserve voltage stabilizer (servo-controlled)
Stabilizer output isolator
System
Parallel configuration (distributed parallel)
Operating temperature up to 50 °C with derating
Operating altitude up to 4500 m with derating
Redundant monitored fans
Space heater with thermostat or hygrostat
Mechanical
Top cable entry
Special frame color (RAL paint standards)
Special feet height 200 mm or base frame
Communication
Additional volt-free contacts (up to 20 relays)
Modbus RTU (RS232 or RS485) ; TCP-IP / Profibus / SNMP
PPVIS monitoring software
FP70ZE Presentation
The Chloride® FP70ZE Uninterruptible Power Supply (UPS) is a true industrial UPS system offering a full-IGBT innovative design and embedding all the latest technologies in power protection.