Chloride® FP70ZE AC UPS

Industrial UPS system with innovative full IGBT design. A wide range of benefits such as low THDi, low power factor, high efficiency, small footprint.

Enquire

UPS TypeAC IEC/UL

Ratings5 to 80 kVA

TechnologyFull IGBT

Chloride® FP70ZE AC UPS

Industrial UPS system with innovative full IGBT design. A wide range of benefits such as low THDi, low power factor, high efficiency, small footprint.

Enquire

UPS TypeAC IEC/UL

Ratings5 to 80 kVA

TechnologyFull IGBT

Market & Industry Type

  • Decarbonisation (Solar, CCS, H2, Wind Turbines)

  • Petrochemical and Chemical

  • Minings/Metals

  • Power generation plants

  • Water and Wastewater

  • Transportation (rail, metro, tramway)

  • Continuous manufacturing processes

Key advantages

Fooprint

Compact footprint -20% to -45% vs traditional technologies

CO2 footprint

Reduction up to -25%

Battery innovation

Sodium Metal Chloride (SMC) batteries integration 

Safety

Bidirectional rectifier to perform battery deep discharging.

Smart access to UPS data

Large color HMI touch-pad for better user interface.

USB access

Export of all the recorded events using USB flash drive.

Best-in-class performance to optimize expenses

Reduced CAPEX - Upstream transformer, switchgear and cables are downsized thanks to high input power factor, low THDi rejection and low inrush current.

Proven digital Vector Control technology to control the output waveform, even on non linear loads.

Controlled OPEX

Lower power consumption thanks to high efficiency

Industrial-grade maintainability

Innovative design allowing an easy front access to all components.

Industrial flexibility

Fit-for-purpose battery selection.

Galvanic isolation: either output and/or input transformers.

Wide range of electrical and mechanical options.

Input

AC Voltage

3-ph+N 208...690 Vac ph-ph ± 10 % (tolerances depend on the voltages)

 

Inrush current 

≤ 1 In (without input transformer)
≤ 8 In (with input transformer)

Power factor

Up to 0.99

Frequency range

50 Hz (60 Hz factory setting) ± 5 %

Embedded input features

AC input isolator switch
Surge protection with MOV lightning arrestors

Max allowed voltage distortion, THDv from mains

8%

Output

AC Voltage

1-ph: 230 Vac (208, 220, 240) ; 110 Vac (115, 120, 127)
3-ph: 400 Vac (380, 415) ; 208 Vac (190, 200, 220)

Frequency stability

With internal oscillator ± 0.1 %
With reserve synchronism ± 1 % (1 to 4 % adjustable)

Voltage stability
(0-100% load variation)

Static ± 1 % Dynamic VFI SS 11 as per IEC62040-3, class 1

Overload inverter
(in % of nominal power)

150 %/1 min - 125 %/10 min at nominal output voltage

Short-circuit clearance
(in % of nominal current)

1-ph and 3-ph: 250 %/100 ms - 150 %/5 s

Voltage distorsion

With 100 % linear load < 2 %
With 100 % non linear load < 5 % as per IEC62040-3

Allowable power factor

0.5 lagging to 0.5 leading

Allowable crest factor

3/1

Embedded output features

Output switch
Output isolation transformer class H

Battery

Battery

SMC (Sodium Metal Chloride) , Lead acid or nickel cadmium, vented or recombination

Recommended number of cells
Lead Acid

110 Vdc (52 to 72)
220 Vdc (104 to 132)
400 Vdc (174 to 220)

Recommended number of cells
Nickel Cadmium

110 Vdc (88 to 94)
220 Vdc (176 to 184)
400 Vdc (296 to 307)

Battery current limitation

0.1 C (Lead Acid) / 0.2 C (Nickel Cadmium)

Embedded battery features

Inbuilt battery circuit breaker with aux. contact
Battery reverse polarity protection and indication
Battery Low Voltage Disconnection (LVD)
Battery test, automatic or manual mode
Battery room temperature sensor for battery charge compensation

General Data

Efficiency

Up to 91 % (according to rating and config.)

Operating temperature

From 0 to 40 °C (without system derating)

T°C operating / Storage

0...40 °C without derating system / -20...70 °C battery excluded

Relative humidity

< 95 % non condensing at 20 °C
 

Operating altitude

1000 m (without system derating)

Cooling

Fan assisted

Ingress protection

Internal IP20 - external IP42

Noise (at 1m in front of the unit)

62 to 72 dB (according to rating)

Input/output isolation

2500 VAC / 1 minute

Feet

100 mm height with feet cover

Gland plate

Aluminium non-magnetic, 3 mm thickness

Dimensions & colour

From 1 x 800 mm to 2 x 1200 mm width / RAL 7035

Embedded system features

Internal cabinet lighting / Lifting Eyes
Auxiliary power socket

Display languages

English, French, Spanish (factory settings)

Output Power (kVA)

110 Vdc

5 / 10 / 20 kVA

220 Vdc

10 / 20 / 30 / 40 / 50 / 60 kVA

400 Vdc

40 / 50 / 60 / 80 kVA

Standards

IEC62040-1

Semiconductor converters - Part 1-1: Specification of basic requirements

IEC62040-2

Electromagnetic compatibility (EMC) - Part 6-2: Generic standards - Immunity for industry

IEC62040-3

Electromagnetic compatibility (EMC) - Part 6-4: Generic standards - Emission for industry

IEC61439-1

Low voltage switchgear and controlgear assemblies - Part1: General rules

Other

Type tests for rectifier-battery charger and batteries

Conformity

Low voltage directive

2006/95/EC (before April 2016)
2014/35/EU (after April 2016)

EMC directive

2004/108/EC (before April 2016)
2014/30/EU (after April 2016)

CE Mark

Yes

Intermediate DC Circuit

Nominal DC Voltage

110 / 220 / 400 Vdc

Voltage stability in steady state

≤ 1 % in float mode (input within tolerance)

Voltage ripple

≤ 1 % RMS (with and without battery connected)

Current limitation

I nominal

Charging characteristic

IU according to DIN 41773

Options

Rectifier

Input isolation transformer
Special 1-ph or 3-ph input voltage (up to 3 x 690 Vac)
Input voltage tolerance from - 20 % to + 15 %
Input circuit breaker with aux. contact and breaking capacity up to 70 kA
Reverse phase sequence alarm Automatic input phase failure adaptation

Battery

Protection box (circuit breaker), black start, automatic or manual mode ; DC earth fault detection

Output

Circuit breaker with aux. contact
Emergency Power Off

Reserve

Circuit breaker with aux contact
Reserve isolation transformer (H class)
Reserve voltage stabilizer (servo-controlled)
Stabilizer output isolator

System

Parallel configuration (distributed parallel)
Operating temperature up to 50 °C with derating
Operating altitude up to 4500 m with derating
Redundant monitored fans
Space heater with thermostat or hygrostat

Mechanical

Top cable entry
Special frame color (RAL paint standards)
Special feet height 200 mm or base frame

Communication

Additional volt-free contacts (up to 20 relays)
Modbus RTU (RS232 or RS485) ; TCP-IP / Profibus / SNMP